Products

Opti Ups

Opti UPS TS2250B Thunder Shield Automatic Voltage Regulator AVR 2000VA 1200W Line Interactive Retail

Upgrade to unlock this product
  • Shipping Cost (lower 48): $47.52
  • SKU: ASI5966
  • Asin: B004K6MCL0
  • Manufacturer Part #: TS2250B
  • Qty Available: 8
  • Shipped By: 6 days
  • Stock: In Stock

Please login to view pricing details.

Product Description

  • Line interactive design.
  • Boost and buck AVR (Auto Voltage Regulation).
  • Fully digitized microprocessor control.
  • Energy saving function (UPS green mode).
  • 50 / 60 Hz frequency auto sensing and selection.
  • Cold start function (DC power on).
  • Lightning and surge protection.
  • Short circuit and overload protection.
  • Advanced battery management (ABM technology).
  • USB communication port.
  • Tel / Modem / LAN surge protection.
  • Automatic charging when UPS is off.
  • History record of power failure events.
  • Back up, on-line, battery status, power status display by software.
  • Scheduled shutdown & reboot.
  • Supports OPTI-SAFE Xtreme and OPTI-SAFE Sentinel power management software.
    Input:

  • Maximum Capacity: 1200W.
  • Nominal Input Voltage: 100/110/120V.
  • Nominal Input Frequency: 50/60Hz Auto sensing.
  • Input Voltage Range: Rated Voltage +/- 25%.
  • Input Short Protection: Fuse.
  • AC Line-In Plug: 110/120V models - NEMA 5-15P.

    Output:

  • Nominal Output Voltage: 100/110/120Vac.
  • Output Voltage Regulation: Rated Voltage +/- 5%.
  • Transfer Time (Typical): 4 ms (typical).
  • Auto Restart: Yes.
  • Start on Battery: Yes.

    Automatic Voltage Regulator (AVR):

  • When the input voltage is 9 % to 25 % lower than that of mains, AVR raises the voltage by 15 % automatically.
  • When the input voltage is 9 % to 25 % higher than that of mains, AVR lowers the voltage by 13 % automatically.
  • Type and Number of Outlets: 110/120V - NEMA 5-15R 2xBattery Backup.

    Communications Interface:

  • Communication Port [1]: RJ11 / RJ45.
  • Data Line Surge Protection: RJ11 / RJ45.

    Protection:

    Surge Energy Rating:

  • 460 Joules (IEC outlets models).
  • 265 Joules (NEMA outlets models).
  • Overload Protection: UPS automatic shutdown if overload exceeds 110% from nominal UPS capacity over 60 seconds or 130% over 3 seconds.
  • Short Circuit: UPS output immediate cut off or input fuse protection.
  • User Replaceable Battery: RBAT-92.
  • Typical Back-up Time [2]:: 45 minutes.
  • Full load runtime: 2 minutes.
  • Half load runtime: 5 minutes.
  • Recharge Time to 90%: 4 hours.
  • Protection: Auto discharge protection.

    Advance Warning Diagnostics:

  • Front Panel LEDs: Power Status / AC Mode / Battery Mode / Battery Fault / Overload.
  • Audible Alarms: Battery Mode / Battery Low / Overload.

    Environmental Parameters:

  • Operating Temperature: 0°~40°C / 32°~104°F.
  • Storage Temperature: -20°~60°C / -4°~140°F.
  • Audible Noise: < 40 dBA.
  • Dimensions (LxWxH):: Physical - 12.5x3.8x5.3 inches / 320x97x135 mm.

    Conformance:

  • EMI/RFI Compatibility: CE.
  • Safety Certifications: CE; UL.